APPLICATIONS

Where are fire-rated doors required?

To know where to expect fire-rated doors within a building, consider the drivers of the codes. First, the codes aim to provide life safety, ensuring occupants have a safe path of egress in the event of a fire. As such, fire-rated doors are commonly found at points of egress to create evacuation pathways through entrances, exits, lobbies and stairwells. Second, the codes look to stop the spread of fire, both to adjacent structures and to other areas of the building, so fire-rated doors may be required in some exterior applications such as curtain wall systems, storefronts and office assemblies.

The International Building Code (IBC) is in use throughout the U.S., but the version in use varies by jurisdiction, which has important implications for allowable fire-rated door and glass products. The International Code Council’s (ICC) next set of IBC updates is scheduled for a 2023 release.

It is recommended to consult the ICC and the local authorities having jurisdiction (AHJ) to determine which codes are needed to follow (See below, “Fire-rated door codes and standards to know”). The precise requirements on a project will depend on the codes and standards adopted in the project’s local jurisdiction. Even if your jurisdiction is not using the latest code edition, to enhance occupant safety in your buildings, consider using a more rigorous, updated code. The ICC frequently debates and revises codes applicable to fire-rated glass, taking into account the latest research and product options.

Fire-Rated Door Codes and Standards to Know

The fire-rated codes that dictate building requirements are the International Code Council’s International Building Code, International Fire Code and International Existing Building Code, and National Fire Protection Association’s Life Safety Code, NFPA 101. These codes are regularly updated, so it’s important to verify the version of the code in use in every project jurisdiction.

Fire-rated doors are tested in accordance with the following standards; as such it is important to know:

  • UL 10B, Fire Tests of Door Assemblies (neutral or negative pressure)
  • UL 10C, Positive Fire Pressure Tests of Door Assemblies
  • NFPA 252, Standard Methods of Fire Tests of Door Assemblies, and/or
  • CAN4 S-104, Standard Method for Fire Tests of Door Assemblies

Additional notable performance standards to be familiar with include:

  • UL 1784, Standard for Air Leakage Tests of Door Assemblies and Other Opening Protectives
  • ANSI Z97.1, Safety Glazing Materials Used in Buildings – Safety Performance Specifications and Methods of Test
  • CPSC 16 CFR 1201, Safety Standard for Architectural Glazing Materials, for Category I or II as indicated in Table 2406.1.

What is the difference between a fire-rated door assembly and a fire-rated opening?

A fire-rated door assembly is a combination of the door, glass, frame, hardware and other component parts that work together to provide a specific degree of fire protection between two separate compartments. Fire-rated openings typically refer to the fire-rated glass and frames used to create windows, sidelites and transoms.

A fire-rated window, sidelite or transom may be included in a door assembly or storefront system. If it is required to meet temperature rise criteria, fire-resistive glass like TGP’s Pilkington Pyrostop® is a code-approved option. In addition, the rating of the sidelite and transom must equal that of the wall, not of the door opening.


Are storefronts fire-rated?

Code requirements for fire-rated storefronts depend on their application—interior or exterior. View the sections below to learn more about each application.

Interior Storefronts

The requirements for interior fire-rated storefronts largely depend on if they provide a means for egress. Those that do must be fire-rated. The precise requirements on a project will depend on the codes and standards adopted in the project’s local jurisdiction. A state or city may adopt a different version of a code or standard that will affect which fire-rated products can be used. Check with the local authority having jurisdiction to verify requirements in the project location.

When an interior fire-rated storefront is necessary, Technical Glass Products’ (TGP) clear fire-rated glass and narrow fire-rated framing can provide a close visual match to non-rated systems. They are representative of traditional windows and storefronts and can be installed into finished openings. Available with fire ratings up to 120 minutes, this comprehensive line of products not only satisfies fire-rated requirements but can match a wide array of aesthetics with narrow steel, aluminum or hardwood offerings.

Exterior Storefronts

The International Building Code (IBC) currently requires exterior walls that are 10 feet or less from the property line to have a fire-resistance rating (ensures assembly is rated for exposure to fire from both sides). The rating is determined by proximity to adjacent buildings, as well as interior occupancy conditions. The fire separation distance also determines allowable openings and size limitations, as defined in Table 705.8 of the IBC. If an exterior storefront falls within these designations, it must meet the necessary fire-rated designations.

As property setbacks grow narrower and drive more exterior storefronts to be fire-rated, they can still offer an opportunity to elevate a building’s design aesthetic. TGP has developed narrow fire-rated framing that can support increased glass lite sizes. When used in lieu of traditional storefront materials, these fire-rated systems provide critical fire safety while also supporting daylighting goals.

Sign up for TGP's Newsletter

Send me emails about product info, continuing education opportunities and other news from Technical Glass Products

Click here to dismiss this window.

By clicking submit, you agree to this web site’s terms of use. To unsubscribe from receiving emails from Technical Glass Products, click the Unsubscribe link at the bottom of our emails or contact Allegion at dataprivacy@allegion.com. You understand and agree that your information may be transferred into the United States or other locations outside your country of residence. For more information on our privacy practices, please see our Privacy Policy.