EXPERT INSIGHTS

All Expert Insights

Selecting the Right Interior Glass Partition System: A Guide to Fire-Rated Glass

David Vermeulen, North America Sales Director, Technical Glass Products

Interior glass partition systems can be integral to facilitating visual connection between spaces within the built environment and drawing daylight deep into the heart of a building. The importance of glass to modern design is implied with the many systems available to project teams, such as:

  • Sidelites and transoms
  • Transparent curtain walls
  • Butt-glazed glass wall systems
  • Channel glass assemblies
  • Half-lite and full-lite glass doors
  • Glass floor systems

While all applications of interior glazing assemblies can support more open and light-filled designs, there are instances where these systems may be called on to provide additional performance capabilities, such as meeting fire- and life-safety code requirements.

Engineering a fire-rated glass partition can require different considerations than architectural glazing to achieve both code compliance and aesthetic goals. The following provides a guide on navigating the many options design teams have.

Opening protectives: the first step to a full fire-rated glass partition

Interior glass partition systems can span full walls and even multiple stories, but not all of them do. This is the case with opening protectives. Under the International Building Code (IBC), opening protectives generally are not to exceed 25 percent of the fire barrier wall length. Despite the difference in size, opening protectives, whether they are fire-protective-rated glass window panels or full-lite fire-rated doors, can support a transparent and open aesthetic.

These fire-rated glass partitions can offer ratings up to 180 minutes according to UL Systems (UL) standards UL 9, UL 10B, UL 10C as well as standards from the National Fire Protection Association (NFPA) NFPA 80, NFPA 252 and NFPA 257. While these products and systems can provide a flexible fire-rated solution, model building codes do place some constraints on their use.

For instance, Section 716: Opening Protectives in the 2024 edition of the International Building Code (IBC), lists where fire-protection-rated glass can be used within the built environment, ratings requirements and sizes allowed before a fire-resistance-rated glass partition is needed. While the IBC provides the basis for many local code requirements, design teams are encouraged to reference local building codes for exact requirements and clarify ambiguities with an Authority Having Jurisdiction (AHJ).

Going beyond the opening with glass wall systems

When an interior glass partition system is greater than 25 percent of the total wall area or is located within a wall or partition that requires fire-resistance, the assembly will likely need a fire rating in accordance with ASTM International (ASTM) E119 or UL 263 standards.

Fire-resistance-rated glass wall systems can support transparent compartmentation efforts in large spaces or maintain means of egress systems while allowing visual connection and daylight access by allowing floor-to-ceiling and wall-to-wall glass systems. This is particularly true for fire-rated, butt-glazed assemblies, which eliminate the need for vertical mullions to maximize the glazing area.

More generally, interior fire-rated glass partitions can create transparent storefronts (complete with fire-rated glass doors), full glass walls, expansive sidelites and transoms and much more. They can also create single-story fire partitions. All of these uses support more open floorplans throughout the built environment.

Fire-rated glass curtain walls reach new heights

Transparent fire-rated design can extend beyond single floor interior glass partition systems. Fire-rated glass curtain walls allow project teams to plan multistory expanses without compromising fire and life safety. This allows design teams to pull light from exterior openings deeper into the built environment. When these glazing systems incorporate narrow-profile steel framing systems, they can offer a close visual match to adjacent, non-rated systems.

Further, systems like Fireframes® Curtainwall Series from Technical Glass Products (TGP) can also be used for exterior applications. Air and water pressure tested and approved for exterior use and fully compatible full-lite fire-rated glass doors, these fire-rated glass curtain walls allow transparent design when a building’s façade also needs to defend against fire and life safety threats.

Fire-rated glass curtain walls, along with interior fire-rated glass partitions, expand the ability for project teams to create code-compliant buildings that also meet occupant wellness goals both now and in the future.

Fire-rated glass wall systems and sustainability

Fire-rated glass assemblies offer a design-forward solution for achieving fire- and life-safety code compliance in and around the built environment. In and of itself, this allows project teams more expansive options for boundary-pushing buildings. But these fire-rated glass partitions can also support more sustainable approaches to construction.

For instance, several fire-rated glazing options from TGP have Environmental Product Declarations (EPDs), which offer transparent documentation on their environmental impact. This documentation and the design benefits of these and other glazing systems can help projects earn credits toward LEED certification.

For teams that know what ratings their project needs but do not know all their options, TGP’s Product SpeciFire® allows designers to input their fire-rated needs to discover which systems are appropriate to specify. Try it out then contact TGP for more complete engineering information.