Fire-Protective: Protects against flames and smoke
Fire-Resistive: Protects against flames, smoke AND heat transfer (meets ASTM E119/UL 263)

Fire-Rated Glass

Fire-Protective Options
Protect against flames and smoke



FireLite®

20-90 Minutes

Fire-Rated Glass Ceramic

Fire Rating (Minutes)

20/45/60/90
Key Characteristic

Glass Ceramic
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

No
Passes Positive Pressure Test

Yes
Meets Energy Codes

No
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Storefront/Window
Classification*

Fire-Protective
FireLite Plus®

20-180 Minutes

Fire-Rated, Safety-Rated Glass Ceramic

Fire Rating (Minutes)

20/45/60/90/120/180
Key Characteristic

Laminated Glass Ceramic
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

No
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window
Classification*

Fire-Protective
FireLite® NT

20-180 Minutes

Fire-Rated, Safety-Rated Glass Ceramic with Surface-Applied Film

Fire Rating (Minutes)

20/45/60/90/120/180
Key Characteristic

Glass Ceramic with Surface-Applied Approved Fire-Rated Film
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

No
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window
Classification*

Fire-Protective
FireLite® IGU

20-180 Minutes

Fire-Rated or Fire/Impact Safety-Rated Insulated Glass Units

Fire Rating (Minutes)

20/45/60/90/120/180
Key Characteristic

Glass Ceramic Insulated Glass Unit
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

Yes
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window
Classification*

Fire-Protective
WireLite®

45 Minutes

Fire-Rated, Wired Glass

Fire Rating (Minutes)

45
Key Characteristic

Wired Glass
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

No
Passes Positive Pressure Test

Yes
Meets Energy Codes

No
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Storefront/Window
Classification*

Fire-Protective
WireLite® NT

20-90 Minutes

Fire-Rated, Impact Safety-Rated Wired Glass with Surface-Applied Film

Fire Rating (Minutes)

20/45/60/90
Key Characteristic

Wired Glass with Surface-Applied Approved Fire-Rated Film
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

No
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window
Classification*

Fire-Protective
Fireglass®20

20 Minutes

Fire-Rated, Safety-Rated Glass

Fire Rating (Minutes)

20
Key Characteristic

Tempered Wireless Glass
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

No
Passes Required Hose Stream Test

No
UL Classified and Labeled

Application

Doors
Classification*

Fire-Protective
Pilkington Pyrostop®

45 Minutes

Fire-Rated, Impact Safety-Rated Transparent Wall Panels

Fire Rating (Minutes)

45 Minutes
Key Characteristic

Transparent Multi-Laminate Wall Panel
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

Yes
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window, Walls
Classification*

Fire-Resistive

Fire-Resistive Options
Protect against flames, smoke AND heat transfer (meets ASTM E119/UL 263)



Pilkington Pyrostop®

60-120 Minutes

Fire-Rated, Impact Safety-Rated Transparent Wall Panels

Fire Rating (Minutes)

60/90/120
Key Characteristic

Transparent Multi-Laminate Wall Panel
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

Yes
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window, Walls, Floor/Ceiling
Classification*

Fire-Resistive
Pilkington Pyrostop® with School Guard Glass®

Up to 120 Minutes

Fire-Rated, Forced Entry and Bullet Resistant Transparent Wall Panel

Fire Rating (Minutes)

45/60/90/120
Key Characteristic

Forced Entry and Bullet Resistant Transparent Multi-Laminate Wall Panel
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

Yes
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window, Walls, Floor/Ceiling
Classification*

Fire-Resistive
Pilkington Pyrostop® with Smartgard®

Up to 120 Minutes

Forced Entry and Bullet Resistant Transparent Multi-Laminate Wall Panel

Fire Rating (Minutes)

45/60/90/120
Key Characteristic

Transparent Multi-Laminate Wall Panel
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

Yes
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window, Walls, Floor/Ceiling
Classification*

Fire-Resistive
Pilkington Pyrostop® BR

Up to 120 Minutes

Fire-Rated and Bullet-Resistant-Rated Transparent Wall Panel

Fire Rating (Minutes)

45/60/90/120
Key Characteristic

Bullet Resistant Transparent Multi-Laminate Wall Panel
High Impact Safety
(CPSC 16 CFR1201 CAT. I AND II)

Yes
Passes Positive Pressure Test

Yes
Meets Energy Codes

Yes
Passes Required Hose Stream Test

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window, Walls, Floor/Ceiling
Classification*

Fire-Resistive

Fire-Rated Framing

Storefront/Window
Fire-Protective: Protects against flames and smoke
Fire-Resistive: Protects against flames, smoke AND heat transfer (meets ASTM E119/UL 263)



Fireframes® Aluminum Series

45 Minute

Fire-Protective-Rated Frames

60/120 MINUTE

Fire-Resistive-Rated Frames

Narrow profiles allow unlimited areas of glazing in fire separations.

Fire Rating (Minutes)

45/60/120
Key Characteristic

Narrow sightlines using extruded aluminum frames
Available in Stainless Steel?

No
UL Classified and Labeled

Application

Doors**, Storefront/Window
Classification*

Fire-Protective: 45 Minutes
Fire-Resistive: 60 Minutes +
Location

Interior or Exterior
Fireframes TimberLine® Series

45/60/120 Minute

Fire-Rated Frames

Features high strength steel sub-frame with a real wood veneered metal cover cap.

Fire Rating (Minutes)

45/60/120
Key Characteristic

High strength steel sub-frame with a variety of real wood veneered cover cap options
Available in Stainless Steel?

No
UL Classified and Labeled

Application

Doors**, Storefront/Window
Classification*

Fire-Protective: 45 Minutes
Fire-Resistive: 60 Minutes +
Location

Interior only

Storefront/Window and Door
Fire-Protective: Protects against flames and smoke
Fire Resistive: Protects against flames, smoke AND heat transfer (meets ASTM E119/UL 263)



Fireframes® Designer Series

20/45/60/90 Minute

Fire-Protective-Rated Doors & Frames

60/90 Minute

Fire-Resistive-Rated Doors

A sleek, modern alternative to traditional hollow metal steel frames.

Fire Rating (Minutes)

20/45/60/90
Key Characteristic

Sleek alternative to hollow metal steel frames
Available in Stainless Steel?

Yes
UL Classified and Labeled

Application

Doors, Storefront/Window
Classification*

Fire-Protective: 20-90 Minute Doors & Frames
Fire-Resistive: 60-90 Minute Doors
Location

Interior or Exterior
Fireframes® Heat Barrier Series

60/90/120 Minute

Fire-Resistive-Rated Doors and Frames

Combine with Pilkington Pyrostop® glass to provide a barrier to radiant and conductive heat transfer.

Fire Rating (Minutes)

60/90/120
Key Characteristic

Narrow steel profiles that provide a barrier to heat transfer
Available in Stainless Steel?

No
UL Classified and Labeled

Application

Doors, Storefront/Window
Classification*

Fire-Resistive
Location

Interior or Exterior
TGProtect FR System

20/45/60 Minute

Fire-Protective-Rated Door and Sidelite(s)

Fire-rated and tested to forced entry standards.

Fire Rating (Minutes)

20/45/60 Minute
Key Characteristic

Fire-Protective-Rated Door and Sidelite(s)
Available in Stainless Steel?

No
UL Classified and Labeled

Intertek certified system tested to ASTM E2395

Application

Door and sidelite
Classification*

Fire-Protective
Location

Interior or Exterior

Walls
Fire-Protective: Protects against flames and smoke
Fire-Resistive: Protects against flames, smoke AND heat transfer (meets ASTM E119/UL 263)



Fireframes ClearView® System

60/120 Minute

Fire-Resistive-Rated Frames

Features nearly colorless transitions between butt-glazed glass with a heat-resistive perimeter frame.

Fire Rating (Minutes)

60/120
Key Characteristic

Nearly colorless transitions between butt-glazed glass with a heat-resistive perimeter frame
Available in Stainless Steel?

No
UL Classified and Labeled

Application

Walls
Classification*

Fire-Resistive
Location

Interior only
Fireframes® Curtainwall Series

45 Minute

Fire-Protective-Rated Frames

60/120 Minute

Fire-Resistive-Rated Frames and Curtain Walls

Allows for large, multi-story expanses of glass in interior and exterior applications using narrow steel profiles.

Fire Rating (Minutes)

45/60/120
Key Characteristic

Narrow steel profile curtain wall system
Available in Stainless Steel?

Yes
UL Classified and Labeled

Application

Fire-Protective: Windows
Fire-Resistive: Walls
Classification*

Fire-Protective: 45 Minutes
Fire-Resistive: 60 Minutes +
Location

Interior or Exterior
Fireframes SG Curtainwall® Series

45/60/120 Minute

Fire-Rated Steel Curtain Wall

Create large, fire-rated glazed walls with the monolithic appearance of a structural silicone glazed system.

Fire Rating (Minutes)

45/60/120
Key Characteristic

Smooth, monolithic curtain wall system
Available in Stainless Steel?

Yes
UL Classified and Labeled

Application

Fire-Protective: Windows
Fire-Resistive: Walls
Classification*

Fire-Protective: 45 Minutes
Fire-Resistive: 60 Minutes +
Location

Interior or Exterior

Floor/Ceiling
Fire Resistive: Protects against flames, smoke AND heat transfer (meets ASTM E119/UL 263)



Fireframes ClearFloor® System

60/120 Minute

Fire-Resistive-Rated, Safety-Rated Glass Floor System

This advanced glass floor system is impact-resistant and fire-rated for two hours.

Fire Rating (Minutes)

60/120
Key Characteristic

Impact-resistant floor system
Available in Stainless Steel?

No
UL Classified and Labeled

Application

Floor/Ceiling
Classification*

Fire-Resistive
Location

Interior only
Sign up for TGP's Newsletter

Send me emails about product info, continuing education opportunities and other news from Technical Glass Products

Click here to dismiss this window.

By clicking submit, you agree to this web site’s terms of use. To unsubscribe from receiving emails from Technical Glass Products, click the Unsubscribe link at the bottom of our emails or contact Allegion at dataprivacy@allegion.com. You understand and agree that your information may be transferred into the United States or other locations outside your country of residence. For more information on our privacy practices, please see our Privacy Policy.