Features
- Protection against radiant and conductive heat transfer
- Barrier to fire and smoke
- Fire-rated for up to 2 hours with required hose stream test
- Impact safety-rated - meets ANSI Z97.1 and CPSC 16CFR1201 (Cat. I and II)
- Wireless with nearly the same clarity as ordinary float glass
- For use in interior and/or exterior applications
- May be lightly sandblasted or etched on one side without affecting fire rating.
- Available in insulated units with other glass products including (but not limited
to):
- Tinted
- Low-E
- One-way Mirror
- Reflective
- Art Glass
- Security Glass
- Available with Level III bullet resistance rating
- Multi-laminate, not a sensitive polymer gel unit
- Pilkington Pyrostop can be combined with Vision Control® integrated cord-free
louvers in a UL-tested fire protection-rated glazing system available directly from
Unicel Architectural
Sales of Pilkington Pyrostop are a cooperative effort between Technical Glass Products
and Pilkington North America.
Listings (Interior)

Listed with Underwriters Laboratories, Inc.® File numbers are R16644 (doors and windows) and R16132 (walls). Tests performed in accordance with ASTM E-119, CAN/ULC-S101, ASTM E2074, ASTM E2010, UL 263, UL 9, UL 10B, UL 10C, CSFM 43.7, NFPA 80, NFPA 251, NFPA 252, NFPA 257, UBC 43.2, UBC 43.4, UBC 7-2, CAN4 S-104 and CAN4 S-106. Approved for use in New York City: MEA 241-00-M. Approved for use in Los Angeles: LARR 25798.
Interior Use
Fire
Rating |
45 min. |
60 min. |
90 min. |
2 hr. |
Manufacturer's
Designation |
45-200
|
60-101
|
90-102
|
120-104
|
Supply
Form |
Single Glazing
|
Single Glazing
|
Single Glazing
|
I.G. Units
|
Nominal
Thickness |
3/4" (19 mm)
|
7/8" (23 mm)
|
1-7/16" (37 mm)
|
2-1/8" (54 mm)
|
Weight
approx.
(lb/ft2) |
9.2
|
11.3
|
17.6
|
21.7
|
| U-Value |
.86
|
.83
|
.74
|
.44
|
Daylight
Trans.
approx. (%) |
86
|
87
|
84
|
74
|
STC Rating
approx. (dB) |
40
|
41
|
45
|
46
|
Max. Exposed
Area (in2)
Other than doors |
4,500
Max. exposed width:
95-1/4"
Max. exposed height:
95-1/4"
|
5,605
Max. exposed width:
96"
Max. exposed height:
96"
|
N/A
|
3,724
Max. exposed width:
111"
Max. exposed height:
111"
|
| Door |
3,724
Max. exposed width:
41-5/8"
Max. exposed height:
89-3/4"
|
3,724
Max. exposed width:
41-5/8"
Max. exposed height:
89-3/4"
|
3,724
Max. exposed width:
41-5/8"
Max. exposed height:
89-3/4"
|
N/A
|
This information is intended for general reference only. For current listing details, please call Technical Glass Products.
Listings (Exterior)

Listed with Underwriters Laboratories, Inc.® File numbers are R16644 (doors and windows) and R16132 (walls). Tests performed in accordance with ASTM E-119, CAN/ULC-S101, ASTM E2074, ASTM E2010, UL 263, UL 9, UL 10B, UL 10C, CSFM 43.7, NFPA 80, NPFA 251, NFPA 252, NFPA 257, UBC 43.2, UBC 43.4, UBC 7-2, CAN4 S-104 and CAN4 S-106. Approved for use in New York City: MEA 241-00-M. Approved for use in Los Angeles: LARR 25798.
Exterior Use
Fire
Rating |
45 min. |
60 min. |
90 min.-2hrs |
Manufacturer's
Designation |
45-200
45-260 (IGU)
45-360* (IGU)
|
60-201
60-261 (IGU)
60-361* (IGU)
|
120-202
120-262 (IGU)
120-362*(IGU)
|
Supply
Form |
Single Glazing
or I.G. Units
|
Single Glazing
or I.G. Units
|
Single Glazing
or I.G. Units
|
Nominal
Thickness |
3/4" (19 mm)
IGU - 1-5/16" (33 mm)
|
1-1/16" (27 mm)
IGU - 1-5/8"
(41 mm)
|
1-9/16" (40 mm)
IGU - 2-1/8" or 2-3/8"
(54 mm) or (60 mm)
|
Weight
approx.
(lb/ft2) |
9.2
12.5(IGU)
|
12.5
15.8 (IGU)
|
19.5
22.1 (IGU)
|
| U-Value |
45-200/.86
45-260/.49
45-360/.37-.39
|
60-201/.83
60-261/.48
60-361/.37-.39
|
120-202/.72
120-262/.44
120-362/.35
|
Daylight
Trans.
approx. (%) |
84
77 (IGU)
|
86
77 (IGU)
|
85
74 (IGU)
|
STC Rating (single or IGU)
approx. (dB) |
40
|
44
|
46
|
Max. Exposed
Area (in2)
Other than doors |
4,500
Max. exposed width:
95-1/4"
Max. exposed height:
95-1/4"
|
5,605
Max. exposed width:
96"
Max. exposed height:
96"
|
3,724
Max. exposed width:
111"
Max. exposed height:
111"
|
| Door |
3,724
Max. exposed width:
41-5/8"
Max. exposed height:
89-3/4"
|
3,724
Max. exposed width:
41-5/8"
Max. exposed height:
89-3/4"
|
3,724
Max. exposed width:
41-5/8"
Max. exposed height:
89-3/4"
|
*Performance values vary for exterior I.G. units based upon the coating on face 2. Coatings are available in Eclipse Advantage Clear, Solar E Solar Control Low-E and Energy Advantage Low-E. This information is intended for general reference only. For current listing details, please call Technical Glass Products.
Framing Options


When combined with Pilkington Pyrostop® glass, the Fireframes Heat Barrier Series doors and frames provide a barrier to radiant and conductive heat transfer. This system allows fire doors to incorporate large glass panels for aesthetic or security reasons and carry fire ratings from 60 minutes to 2 hours.

The Designer Series doors and frames incorporate precise European engineering, providing a sleek, modern alternative to traditional hollow metal frames.

Designed for maximum durability and performance, the Hardwood Series offers an attractive alternative to traditional hollow metal frames. Available with fire ratings from 20 to 60 minutes, this system can incorporate a wide range of fire-rated glazing materials with glass sizes that surpass traditional systems.

Curtainwall Series allows for large, multi-story expanses of glass in interior and exterior applications. A variety of face cap options are available to customize the look.

Fireframes® Aluminum Series frames combined with Pilkington Pyrostop® glass; provide a barrier to radiant and conductive heat transfer, allowing unlimited areas of glazing in fire separations.

This advanced glass floor system incorporates Pilkington Pyrostop® glass and is impact-resistant and fire-rated for up to two hours – the only glazed floor in North America with that level of protection.

The Fireframes SG Curtainwall™ Series is a patent pending fire-rated curtainwall system that allows for large, multi-story expanses of glass with a smooth flush glazed appearance.
Storage & Handling
Pilkington Pyrostop must be handled with care during transportation, storage, inspection and installation. It should be stored in dry conditions, stocked vertically and fully supported in a manner which prevents the glass from sagging. During storage and transportation, the temperature of Pilkington Pyrostop should not exceed 122° F. Do not expose the "non-PVB" side of the glass to UV light. Do not remove the protective edge tape. See manufacturer's installation and warranty information for further details.
Care & Warranty
To maintain aesthetics, it is important to clean the glass during and after construction. For routine cleaning, use a soft, clean, grit-free cloth and a mild soap, detergent, or nonabrasive window cleaning solution.
Rinse immediately with clean water and remove any excess water from the glass surface with a squeegee. Do not allow any metal or hard parts of the cleaning equipment to contact the glass surface.
Failure to comply with these care and cleaning guidelines may result in loss of warranty.
Download a PDF of our Care & Warranty Brochure.