Listings

Listed and labeled by Underwriters Laboratories, Inc.® as Design Number U558 and Underwriters Laboratories of Canada as CIKV7.R25274-U558. Frame tests performed in accordance with UL 263 / ASTM E-119 (60-120 minutes), CAN/ULC-S101, NFPA 251, UL 9, UL 10C, UBC 7-2 and UBC 7-4. Doors tested in accordance UL 10B, UL 10C, ASTM E2074, and NFPA 252. Approved for use in Los Angeles – LARR 25798.
Max. Size
Maximum Allowable Size Information
Framing
| Rating |
Max. Exposed
Glass Area Per Piece |
Max. Exposed
Glass Dimension |
|
45 Min.*
|
4,500 in2
|
95-1/4"
|
|
60 Min.**
|
5,605 in2
|
96"
|
|
120 Min.**
|
3,794 in2
|
110-3/8"
|
* 45 minute window systems are classified as an Opening Protective as per UL 9, ASTM E2010 with a maximum overall frame size of 144" x 144."
** 60 and 120-minute tests conducted per UL 263 / ASTM E-119. Therefore assembly is classified as a wall assembly, and not subject to “opening" area limitations.
Doors
| Rating |
Max. Single Door Leaf Size |
Max. Exposed
Glass Size Per Piece |
| Fireframes Designer Series |
|
20 Minutes
|
42" x 96"
|
36" x 89"
|
|
45 Minutes
|
42" x 96"
|
36" x 89"
|
|
60 Minutes
|
42" x 96"
|
36" x 89"
|
|
90 Minutes
|
42" x 96"
|
36" x 56-1/2" (divided lite door)
|
| Fireframes Heat Barrier Series*** |
|
60 Minutes
|
42" x 96"
|
41–5/8" x 89–3/4"
|
|
90 Minutes
|
42" x 96"
|
41–5/8" x 89–3/4"
|
***Where temperature rise door is required.
Hardware
All door hardware for Aluminum Series doors is supplied by Technical Glass Products. Please contact Technical Glass regarding your individual hardware requirements.
Standard door hardware package may include:
CAD Details
To obtain CAD files of any of these detail drawings, please use our CAD request form.
Feeling Social?
Check out our
social media sites.
Like us on Facebook, watch our YouTube videos, follow us on Twitter and stay tuned for a few other applications in the works. Interact, share ideas and learn about fire-rated glass and framing in a whole new way.